Passive Intermodulation, 3rd Order1 |
-155 dBc minimum, dynamic HALT |
As per IEC 62037-2, -3, before, during and after HALT testing
|
Operating frequency |
DC - 6 GHz |
|
|
Return Loss (dB)2
|
Frequency (MHz) |
L<20 |
20< L<80 |
80< L<130 |
130< L<170 |
617 - 960 |
-31 |
-26 |
-25 |
-24 |
1700 - 2200 |
-28 |
-26 |
-25 |
-23 |
2200 - 2700 |
-27 |
-24 |
-22 |
-20 |
3400 - 4200 |
-24 |
-20 |
-18 |
-16 |
5150 - 5925 |
-16 |
-16 |
-16 |
-16 |
|
Return Loss (dB)2
|
Frequency (MHz) |
L<20 |
20< L<80 |
80< L<130 |
130< L<170 |
617 - 960 |
-31 |
-26 |
-25 |
-24 |
1700 - 2200 |
-28 |
-26 |
-25 |
-23 |
2200 - 2700 |
-27 |
-24 |
-22 |
-20 |
3400 - 4200 |
-24 |
-20 |
-18 |
-16 |
1 100% of jumpers factory-tested with result available via web-based portal (link below)
2 For mixed interface jumpers, Return Loss specification is governed by the interface with the lowest frequency rating.
Mechanical stress, dynamic
|
Meets electrical performance in above table before, during, and after test. |
As per IEC 62037-2, -3
|
Peak pull strength
|
> 175 lb min, 3/8” superflexible jumpers
|
Cable limited, cable must fail before connection |
Cable torque
|
> 33 lbf·in min, 3/8” superflexible jumpers
|
Cable limited, cable must fail before connection |
Thermal shock
|
Meets electrical performance in above table before and after test.
|
As per Anatel 75, before, during, and after HALT testing
|
Thermal stress
|
Meets electrical performance in above table before, during, and after test.
|
-55 °C to +85 °C, cycled every 2 hours for 30 days minimum
|
Moisture migration
|
Meets electrical performance in above table before, during, and after test. No dye present past seals at 10X magnification.
|
ANSI/SCTE 60 5 day submersion with thermal cycling.
|
Corrosion resistance
|
Corrosion must not penetrate plating into base metals; plating must stay adhered to base metal.
|
ASTM B117-94, 1000 hour duration
|
UV exposure
|
Materials must show no signs of discoloration or embrittlement after 12 months exposure, equal to 33.4 years outdoors. |
Full UV spectrum (UVA, UVB, UVC), 12 months exposure with moisture present per ASTM G155
|
Vibration
|
Meets electrical performance in above table before, during, and after test
|
|
L4MW4RW-38S-8 |
Jumper, 4.3-10 to 4.3-10 RA, 3/8” Superflex, WPS, 8 ft |
L4M4M-38S-25 |
Jumper, 4.3-10 to 4.3-10, 3/8” Superflex, 25 ft |