UXP-NF-12

N Female Connector for 1/2” Annular Cable

General Specification
Interface/gender N female
Cables supported1 Andrew LDF4, LDF4RK, LDF4 RN; RFS LCF12; NK Draka RFA1200; Eupen EC4, Leoni Flexline 1/2"R; LS/Superior Essex HFC 12D, HFAC 12D; Hansen RF5012, RF5012Z; Rosenberger SL 1/2" R
Weight 0.256 lb | 116.1 g
JMA Weather Protection System N/A
Tools required JMA part number Comment
Cable preparation SP-1/2-LDF4D "U" bit
Connector compression HCG-FRAMESET-1/2, HCG-CC Insert B
Hex width 25 mm | 1 in.  
Frequency band VSWR Return loss (dB)
555–1000 MHz (0-1 GHz) 1.02 40
1000–2700 MHz (1-2 GHz) 1.03 38
2700–3800 MHz (2-4 GHz) 1.05 30
3800–6000 MHz (4-6 GHz) 1.08 26
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 60237-02, -3
DC test voltage 2000 V  
Center contact resistance ≤ 1.5 milliohm  
Outer contact continuity 0.3 milliohm max.    
Average power 600 W @ 900 MHz  
Peak power, max. 10 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -120 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined 1.1 kN | >250 lb Cable limited
Cable retention torque 6.7 N·m | 5 lbf·ft Cable limited
Interface durability 50 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

10/24/18