UXP-DM-78

7-16 DIN Male Connector for 7/8” Annular Cable

General Specification
Interface/gender 7-16 DIN Male
Cables supported1 Andrew AVA5, AVA5RK, AL5, LDF5, VXL5; RFS LCF78, UCF78; NK Draka RFA78; Eupen EC5; Leoni Flexline 7/8"R; LS/Superior Essex LHF 22D, LHF-22DU; Hansen RF5078; Rosenberger SL 7/8"
Weight .629 lb | 285.3 g
JMA Weather Protection System WPS-5
Tools required JMA part number Comment
Cable preparation SP-78 No coring required
Connector compression HCG-FRAMESET-7/8, HCG-CC  
Torque wrench TQ-114-F18 18 lbf·ft | 24.4 N·m
Frequency band VSWR Return loss (dB)
555–1000 MHz (0-1 GHz) 1.02 40
1000–2700 MHz (1-2 GHz) 1.03 38
2700–3800 MHz (2-4 GHz) 1.05 30
3800–6000 MHz (4-6 GHz) 1.08 26
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 60237-02, -3
DC test voltage 4000 V  
Center contact resistance ≤0.4 milliohm  
Outer contact continuity 1.5 milliohm max.    
Average power 3000 W @ 900 MHz  
Peak power, max. 40 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -130 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined 1.56 kN | > 350 lb Cable limited
Cable retention torque 21.69 N·m | 16 lbf·ft Cable limited
Interface durability 500 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

10/23/18