| General | Specification | |||
|---|---|---|---|---|
| Interface/gender | 7-16 DIN male | |||
| Cables supported1 | Manufacturer | P/N | Manufacturer | P/N |
| RFS | LCG158 | CommScope | AVA7 | |
| NK Draka | RFA158 | AVA7RK | ||
| Eupen | EC7 | AL7 | ||
| LS/Superior Essex | LHF 42D | VXL7 | ||
| LHF-42DUF | LDF76 | |||
| Rosenberger | SL 1-5/8"R | |||
| Weight | 1.168 lb | 529.8 g | |||
| JMA Weather Protection System | WPS-7 | |||
| Tools required | JMA part number | Comment |
|---|---|---|
| Cable preparation | SP-158 | No coring required |
| Connector compression | HCG-FRAMESET-158, HCG-CC | |
| Torque wrench | TQ-114-F18 | 18 lbf·ft | 24.4 N·m |
| Frequency band | VSWR | Return loss (dB) |
|---|---|---|
| DC-1000 MHz | 1.02 | 40 |
| 1000–2000 MHz | 1.03 | 36 |
| 2000–4000 MHz | 1.05 | 32 |
| 4000–6000 MHz | 1.08 | 28 |
| Electrical | Specification | Comment |
|---|---|---|
| Connector impedance | 50 ohm | |
| Operating frequency band | DC–6 GHz | |
| 3rd order IMD dynamic, (PIM) | -161 dBc, typical | IEC 62037-2 |
| DC test voltage | 4000 V | |
| Center contact resistance | ≤ 0.4 milliohm | |
| Outer contact continuity | 1.5 milliohm max. | |
| Average power | 3000 W @ 900 MHz | |
| Peak power, max. | 40 kW | |
| Insertion loss, typical | 0.05 dB | Per connector |
| Shielding effectiveness | < -130 dB | @ 0-1 GHz |
| Mechanical | Specification | Comment |
|---|---|---|
| Pull force combined | 2.67 kN | >600 lb | Cable limited |
| Cable retention torque | 67.8 N·m | 50 lbf·ft | Cable limited |
| Interface durability | 500 cycles | IEC 61169-4:9.5 |
| Environmental | Specification | Test |
|---|---|---|
| Operating temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
| Storage temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
| Accelerated UV | 1000 hr | ASTM G154 |
| Immersion test method | Mated & unmated, IP68 | IEC 60529:2001 & ANSI/SCTE 60 |
| Water jetting test method | Mated & unmated, IP66 | IEC 60529:2001 |
| Mechanical shock test method | Pass | IEC 60068-2-27 |
| Thermal shock test method | Pass | IEC 60068-2-14 |
| Vibration test method | 100 m/s2, 2 Hz to 200 Hz | IEC 61169-1:2003 |
| Corrosion test method | 1000 hr | IEC 60068-2-11 |
|
|
| ©2025 JMA Wireless. All rights reserved. All products, company names, brands, and logos are trademarks™ or registered® trademarks of their respective holders. All specifications are subject to change without notice. +1 315.431.7100 customerservice@jmawireless.com |
|