UXP-4F-14S

4.3-10 Female Connector for 1/4” Superflexible Cable

General Specification
Interface/gender 4.3-10 Female
Cables supported1 Andrew FSJ1-50A, FSJ1RK-50B, PTS1-50-P; RFS SCF14-50J, SCF14-50JFN; Hansen RF5014S, RF5014SZ; Eupen EC1- 50-HF; Times SPP-250-LLPL, HUBER+SUHNER SUCOFEED 1/4 HFFR, HUBER+SUHNER SUCOFEED 1/4 HF, Times SPO-250
Weight 0.302 lb | 137 g
JMA Weather Protection System N/A
Tools required JMA part number Comment
Cable preparation SP-14S No coring required
Connector compression HCG-FRAMESET-1/4, HCG-CC  
Hex width 19 mm | 3/4 in.  
Frequency band VSWR Return loss (dB)
555–1000 MHz (0-1 GHz) 1.02 40
1000–2700 MHz (1-2 GHz) 1.03 38
2700–3800 MHz (2-4 GHz) 1.05 30
3800–6000 MHz (4-6 GHz) 1.08 26
Electrical Specification Comment
Connector impedance 50 ohm  
Operating frequency band DC–6 GHz  
3rd order IMD dynamic, (PIM) -161 dBc, typical IEC 60237-02, -3
DC test voltage 1600 V  
Center contact resistance ≤ 0.8 milliohm  
Outer contact continuity 1.0 milliohm max.    
Average power 600 W @ 900 MHz  
Peak power, max. 6.4 kW  
Insertion loss, typical 0.05 dB Per connector
Shielding effectiveness < -120 dB @ 0-1 GHz
Mechanical Specification Comment
Pull force combined .67 kN | > 150 lb Cable limited
Cable retention torque 2 N·m | 1.5 lbf·ft Cable limited
Interface durability 100 cycles IEC 61169-4:9.5
Environmental Specification Test
Operating temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Storage temperature -55 °C to +85 °C (-67 °F to 185 °F)  
Accelerated UV 1000 hr ASTM G154
Immersion test method Mated & unmated, IP68 IEC 60529:2001 & ANSI/SCTE 60
Water jetting test method Mated & unmated, IP66 IEC 60529:2001
Mechanical shock test method Pass IEC 60068-2-27
Thermal shock test method Pass IEC 60068-2-14
Vibration test method 100 m/s2, 2 Hz to 200 Hz IEC 61169-1:2003
Corrosion test method 1000 hr IEC 60068-2-11
1For cable types not listed, please contact JMA Technical Support.

10/23/18