|
|
![]() |
|
General | Specification |
---|---|
Interface/gender | 2.2-5 Male, torque type |
Cables supported1 | Andrew LDF4, LDF4RK, LDF4 RN; RFS LCF12, LCF12-50JL; NK Draka RFA1200; Eupen EC4, Leoni Flexline 1/2"R; LS/Superior Essex HFC 12D, HFAC 12D; Hansen RF5012, RF5012Z; Rosenberger SL 1/2" R; Belden RA500, RA500R |
Weight | 107.2 g | 0.236 lb |
JMA Weather Protection System | WPS-N-4A / WPS-2F-12 |
Tools required | JMA part number | Comment |
---|---|---|
Cable preparation | SP-1/2-LDF4D | "U" bit |
Connector compression | HCG-FRAMESET-1/2, HCG-CC | Insert D |
Torque wrench | TQ-916-F2.2 | 2.2 lbf·ft | 2.98 N·m |
Frequency band | VSWR | Return loss (dB) |
---|---|---|
555–1000 MHz (0-1 GHz) | 1.02 | 40 |
1000–2700 MHz (1-2 GHz) | 1.03 | 38 |
2700–3800 MHz (2-4 GHz) | 1.05 | 30 |
3800–6000 MHz (4-6 GHz) | 1.08 | 26 |
Electrical | Specification | Comment |
---|---|---|
Connector impedance | 50 ohm | |
Operating frequency band | DC–6 GHz | |
3rd order IMD dynamic, (PIM) | -161 dBc, typical | IEC 60237-02 |
DC test voltage | 2500 V | |
Center contact resistance | ≤1.0 milliohm | |
Outer contact continuity | 1.0 milliohm max. | |
Average power | 600 W @ 900 MHz | |
Peak power, max. | 15 kW | |
Insertion loss, typical | 0.05 dB | Per connector |
Shielding effectiveness | < -120 dB | @ 0-1 GHz |
Mechanical | Specification | Comment |
---|---|---|
Pull force combined | 1.1 kN | > 250 lb | Cable limited |
Cable retention torque | 6.7 N·m | 5 lbf·ft | Cable limited |
Interface durability | 100 cycles | IEC 61169-4:9.5 |
Environmental | Specification | Test |
---|---|---|
Operating temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
Storage temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
Accelerated UV | 1000 hr | ASTM G154 |
Immersion test method | Mated & unmated, IP68 | IEC 60529:2001 & ANSI/SCTE 60 |
Water jetting test method | Mated & unmated, IP66 | IEC 60529:2001 |
Mechanical shock test method | Pass | IEC 60068-2-27 |
Thermal shock test method | Pass | IEC 60068-2-14 |
Vibration test method | 100 m/s2, 2 Hz to 200 Hz | IEC 61169-1:2003 |
Corrosion test method | 1000 hr | IEC 60068-2-11 |
1For cable types not listed, please contact JMA Technical Support. |
©2020 JMA Wireless. All rights reserved. This document contains proprietary information. All products, company names, brands, and logos are trademarks™ or registered® trademarks of their respective holders. All specifications are subject to change without notice. +1 315.431.7100 customerservice@jmawireless.com |
![]() |