| General | Specification | |||||
|---|---|---|---|---|---|---|
| Interface/gender | N Right angle male | |||||
| Cables supported1 | Manufacturer | P/N | Manufacturer | P/N | Manufacturer | P/N | 
| JMA Wireless | JMA12P-50 | RFS | ICA12-50JPL | Wireless Supply | 12/WP | |
| CommScope | HL4RPV-50 | ICA12-50JPLB | Rosenberger | RLCX-SL012R | ||
| HL4RPV-50B | ICA12-50JPLR | Eupen | EC4-50PL | |||
| HL4RPV-50R | ICA12-50JPLW | Belden | RA500P | |||
| AL4RPV-50 | ICA12-50JPLLR | Acome | HPL 50-1/2F | |||
| HUBER+SUHNER | Sucofeed_1/2_PW | ICA12-50JPLLW | HPL 50-1/2F ALU | |||
| LS/Superior Essex | LHF12DPV | |||||
| Weight | 163.3 g | 0.360 lb | |||||
| JMA Weather Protection System | N/A | |||||
| Tools required | JMA part number | Comment | 
|---|---|---|
| Cable preparation | SP-12PL-01 | Bit “V1” all cables | 
| Connector compression | HCG-FRAMESET-1/2, HCG-CC | Insert A | 
| Torque wrench | TW1412 | 1.58 N·m | 14 lbf·in | 
| Frequency band | VSWR | Return loss (dB) | 
|---|---|---|
| 555–1000 MHz | 1.02 | 40 | 
| 1000–2700 MHz | 1.03 | 36 | 
| 2700–3800 MHz | 1.05 | 32 | 
| 3800–6000 MHz | 1.08 | 28 | 
| Electrical | Specification | Comment | 
|---|---|---|
| Connector impedance | 50 ohm | |
| Operating frequency band | DC–6 GHz | |
| 3rd order IMD dynamic, (PIM) | -161 dBc, typical | IEC 62037-2 | 
| DC test voltage | 2000 V | |
| Center contact resistance | ≤ 1.5 milliohm | |
| Outer contact continuity | 0.3 milliohm max. | |
| Average power | 600 W @ 900 MHz | |
| Peak power, max. | 10 kW | |
| Insertion loss, typical | 0.05 dB | Per connector | 
| Shielding effectiveness | < -120 dB | @ 0-1 GHz | 
| Mechanical | Specification | Comment | 
|---|---|---|
| Pull force combined | .89 kN | > 200 lb | Cable limited | 
| Cable retention torque | 6.7 N·m | 5 lbf·ft | Cable limited | 
| Interface durability | 500 cycles | IEC 61169-4:9.5 | 
| Environmental | Specification | Test | 
|---|---|---|
| Operating temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
| Storage temperature | -55 °C to +85 °C (-67 °F to 185 °F) | |
| Accelerated UV | 1000 hr | ASTM G154 | 
| Immersion test method | Mated & unmated, IP68 | IEC 60529:2001& ANSI/SCTE 60 | 
| Water jetting test method | Mated & unmated, IP66 | IEC 60529:2001 | 
| Mechanical shock test method | Pass | IEC 60068-2-27 | 
| Thermal shock test method | Pass | IEC 60068-2-14 | 
| Vibration test method | 100 m/s2, 2 Hz to 200 Hz | IEC 61169-1:2003 | 
| Corrosion test method | 1000 hr | IEC 60068-2-11 | 
|  | 